5-16
DSC-F707
4. Flange Back Check
Mode CAMERA
Subject Siemens star
(1.0 m from the front of the lens)
(Luminance: 200 to 400 lux)
Measurement Point Check operation on monitor TV
Measuring Instrument
Specified value Focused at the TELE end and
WIDE end
Checking method:
Order Page Address Data Procedure
1
Place the Siemens star 1.0 m
from the front of the lens.
2
To open the IRIS , decrease
the luminous intensity to the
Siemens star up to a point
before noise appear on the
image.
3 0 01 01
4
Perform “Data setting during
camera system adjustment”.
(Refer to page 5-13)
5 B 3D Note down the data.
6 B 3D 50 Press PAUSE button.
7
Shoot the Siemens star with
the zoom TELE end.
8 Turn on the auto focus.
9
Check that the lens is
focused.
10 6 2C 01
11
While observe the TV
monitor, change the zoom to
the WIDE end and check that
the lens is focused.
Processing after Completing Adjustment:
Order Page Address Data Procedure
16 2C00
2B 3D
Set data noted down at step
5, and press PAUSE button.
3
Release the data setting
performed at step 4.
(Refer to page 5-13)
4 0 01 00