5-22
DSC-F707
12. Auto White Balance 3200K Check
Mode CAMERA
Subject Clear chart
(Standard picture frame with the
zoom lens at WIDE end)
Measurement Point Displayed data Video terminal
of Page: 1 of A/V OUT jack
(Note 3) (75 Ω terminated)
Measuring Instrument Adjusting remote Vectorscope
commander
Specified Value R ratio: Fig. 5-1-16
3E00 to 4200
B ratio:
3E00 to 4200
Note 1: Check that the data of page: 6, address: 02 is “00”.
If not, turn the power of unit OFF/ON.
Note 2: Refer to “Picture Frame Setting” for YH and YL.
Note 3: The right four digits of the page: 1 displayed data of the
adjusting remote commander.
1:
XX:XX
Displayed data
Checking method:
Order Page Address Data Procedure
1 0 01 01
2
Perform “Data setting during
camera system adjustment”.
(Refer to page 5-13)
36 2C01
4 6 90 00
5 6 91 00
6 6 92 YL (Note 2)
7 6 93 YH (Note 2)
8 6 01 79 Press PAUSE button.
96 07
Check the data changes to
“01”.
10 6 01 00 Press PAUSE button.
11 9 B4 Note down the data.
12 9 B4 20 Press PAUSE button.
13 6 01 0F Press PAUSE button.
14 0 03 04
15 1
Check that the displayed data
(Note 3) satisfied the R ratio
specified value.
16 0 03 05
17 1
Check that the displayed data
(Note 3) satisfied the B ratio
specified value.
18
Check that the center of the
white luminance point within
the circle shown Fig 5-1-16.
Processing after Completing Adjustment:
Order Page Address Data Procedure
1 6 01 00 Press PAUSE button.
29 B4
Set data noted down at step
11, and press PAUSE button.
3 0 03 00
46 2C00
5 6 92 00
6 6 93 00
7
Release the data setting
performed at step 2.
(Refer to page 5-13)
8 0 01 00