5-18
DSC-F707
6. F No. Compensation
Compensate the unevenness of the iris meter sensitivity.
Mode CAMERA
Subject Clear chart
(Standard picture frame with the
zoom lens at WIDE end)
Adjustment Page F
Adjustment Address 59 to 5D
Note 1: Check that the data of page: 6, address: 02 is “00”.
If not, turn the power of unit OFF/ON.
Note 2: Refer to “Picture Frame Setting” for YH and YL.
Adjusting method:
Order Page Address Data Procedure
1 0 01 01
2
Perform “Data setting during
camera system adjustment”.
(Refer to page 5-13)
36 2C01
4 6 90 00
5 6 91 00
6 6 92 YL (Note 2)
7 6 93 YH (Note 2)
8 6 01 79 Press PAUSE button.
96 07
Check the data changes to
“01”.
10 6 01 00 Press PAUSE button.
11 6 01 BB
Press PAUSE button.
(Note 3)
12 6 02
Check the data changes to
“01”.
Note 3: The adjustment data will be automatically input to page:
F, address: 59 to 5D.
Processing after Completing Adjustment:
Order Page Address Data Procedure
1 6 01 00 Press PAUSE button.
26 2C00
3 6 92 00
4 6 93 00
5
Release the data setting
performed at step 2. (Refer to
page 5-13)
6 0 01 00
7. Mechanical Shutter Adjustment
Adjust the period which the mechanical shutter is closed, and com-
pensate the exposure.
Mode CAMERA
Subject Clear chart
(Standard picture frame with the
zoom lens at WIDE end)
Adjustment Page F
Adjustment Address BC to D5
Note 1: Check that the data of page: 6, address: 02 is “00”.
If not, turn the power of unit OFF/ON.
Note 2: Refer to “Picture Frame Setting” for YH and YL.
Adjusting method:
Order Page Address Data Procedure
1 0 01 01
2
Perform “Data setting during
camera system adjustment”.
(Refer to page 5-13)
36 2C01
4 6 90 00
5 6 91 00
6 6 92 YL (Note 2)
7 6 93 YH (Note 2)
8 6 01 79 Press PAUSE button.
96 07
Check the data changes to
“01”.
10 6 01 00 Press PAUSE button.
11 6 01 AD
Press PAUSE button.
(Note 3)
12 6 02
Check the data changes to
“01”.
13 6 AB Check the data is “00”.
Note 3: The adjustment data will be automatically input to page:
F, address: BC to D5.
Processing after Completing Adjustment:
Order Page Address Data Procedure
1 6 01 00 Press PAUSE button.
26 2C00
3 6 92 00
4 6 93 00
5
Release the data setting
performed at step 2.
(Refer to page 5-13)
6 0 01 00