74
6.8 Single-phase Wireless Meter Networking Procedure (for
SG5.0RS-ADA)
Step 1 Press and hold the function button on WiNet-S2 for 5 10 s, and release it after the
RUN indicator turns to fast blinking in green. The WiNet-S2 is in networking mode.
Step 2 Press and hold the function button on WiMeter-S for 5 10 s, and release it after
the RUN indicator turns to fast blinking in green. The WiMeter-S is in networking mode.
Step 3 Check whether the WiMeter is online.
Log in to iSolarCloud App, select the corresponding plant, and check whether the S/N of "-
Networking Devices" displayed on the "Device" page is consistent with the S/N of the
WiMeter that is manually networked. If it is the same, the WiMeter-S is successfully online.
Step 4 If the WiMeter goes online in step 3, the networking is successful. If the WiMeter
does not come online within 5 minutes, repeat step 1 and 2.
6 Commissioning User Manual

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Sungrow SG10RS and is the answer not in the manual?

Sungrow SG10RS Specifications

General IconGeneral
Rated Power10 kW
Max. DC Voltage1100 V
Number of MPPTs2
Max. Efficiency98.6%
Protection RatingIP65
Start Voltage180 V
Rated AC Output Power10 kW
Max. AC Output Power11 kW
Rated Output Voltage230 V
Operating Temperature Range-25°C to 60°C
TopologyTransformerless
Cooling MethodNatural Convection
Maximum Power Output11 kW
Maximum Input Current25 A
MPPT Voltage Range160-1000 V
Max. DC Input Power15 kW
AC Voltage Range180-280 V
Humidity Range0-100%
CommunicationRS485

Related product manuals