86
7.10.1 System Parameters
Tap Settings→System Parameters to enter the corresponding interface, as shown in the
following figure.
figure 7-12 System Parameters
* The image shown here is for reference only.
Boot/Shutdown
Tap Boot/Shutdown to send the boot/shutdown instruction to the inverter.
For Australia and New Zealand, when the DRM state is DRM0, the "Boot" option will be
prohibited.
Date Setting/Time Setting
The correct system time is very important. Wrong system time will directly affect the data
logging and power generation value. The clock is in 24-hour format.
Software Version
Version information of the current firmware.
7.10.2 Operation Parameters
Running Time
Tap Settings→Operation Parameters→Running Time to enter the corresponding screen,
on which you can set "Connecting Time" and "Reconnecting Time".
figure 7-13 Running Time
PID Parameters
Tap Settings→Operation Parameters→PID Parameters to enter the corresponding
screen, on which you can set "PID Parameters".
7 iSolarCloud App User Manual

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Sungrow SG10RS and is the answer not in the manual?

Sungrow SG10RS Specifications

General IconGeneral
Rated Power10 kW
Max. DC Voltage1100 V
Number of MPPTs2
Max. Efficiency98.6%
Protection RatingIP65
Start Voltage180 V
Rated AC Output Power10 kW
Max. AC Output Power11 kW
Rated Output Voltage230 V
Operating Temperature Range-25°C to 60°C
TopologyTransformerless
Cooling MethodNatural Convection
Maximum Power Output11 kW
Maximum Input Current25 A
MPPT Voltage Range160-1000 V
Max. DC Input Power15 kW
AC Voltage Range180-280 V
Humidity Range0-100%
CommunicationRS485