87
figure 7-14 PID Setting
table 7-4 PID Parameter Description
Parameter
Description
PID Recovery
Set enabling/disabling of the PID night recovery function. PID night
recovery function operates between 22:00 pm and 5:00 am by
default.
Anti-PID
The Anti-PID function is performed during the day when connected
to the grid.
Full-Day PID
Suppression
The function is turned on and the PID is adjusted throughout the
day.
AFCI Parameters(Optional)
Tap Settings→Operation Parameters→AFCI Parameters to enter the corresponding
screen, on which you can set "AFCI Parameters".
figure 7-15 AFCI Setting
7.10.3 Power Regulation Parameters
Active Power Regulation
Tap Settings→Power Regulation Parameters→Active Power Regulation to enter the
screen, as shown in the following figure.
User Manual 7 iSolarCloud App

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Sungrow SG10RS and is the answer not in the manual?

Sungrow SG10RS Specifications

General IconGeneral
Rated Power10 kW
Max. DC Voltage1100 V
Number of MPPTs2
Max. Efficiency98.6%
Protection RatingIP65
Start Voltage180 V
Rated AC Output Power10 kW
Max. AC Output Power11 kW
Rated Output Voltage230 V
Operating Temperature Range-25°C to 60°C
TopologyTransformerless
Cooling MethodNatural Convection
Maximum Power Output11 kW
Maximum Input Current25 A
MPPT Voltage Range160-1000 V
Max. DC Input Power15 kW
AC Voltage Range180-280 V
Humidity Range0-100%
CommunicationRS485