3/6/2018 Proprietary and Confidential - Technicolor 44
Figure 6.10
6.4.3 User provisioning for RIP
To change the configuration, the user needs to click on the parameters and change the
values appropriately and press the save button provided in the page. The specific parameter
configurations are explained below:
RIP can be enabled by selecting the RIP Enable option.
The send version and receive version can be either 1 or 2. If no version is selected,
version 1 would be sent; however both version 1 and 2 can be received
Update interval configures the time interval between route updates default value is
30 seconds.
Metric is a parameter used by RIP in case there are multiple routes were identified
to the same destination. The protocol uses the shortest path to route the packets to
such destinations and it is determined by the metric parameter. Default value is 1.
The user needs to select the Authentication type (Text / MD5), Key and ID to
complete the authentication configuration.