8 Parameter Measurement Information
8.1 Charge Pump Current Specification Definitions
I1 = Charge Pump Sink Current at V
CPout
= V
CC
- ΔV
I2 = Charge Pump Sink Current at V
CPout
= V
CC
/2
I3 = Charge Pump Sink Current at V
CPout
= ΔV
I4 = Charge Pump Source Current at V
CPout
= V
CC
- ΔV
I5 = Charge Pump Source Current at V
CPout
= V
CC
/2
I6 = Charge Pump Source Current at V
CPout
= ΔV
ΔV = Voltage offset from the positive and negative supply rails. Defined to be 0.5 V for this device.
8.1.1 Charge Pump Output Current Magnitude Variation Vs. Charge Pump Output Voltage
8.1.2 Charge Pump Sink Current Vs. Charge Pump Output Source Current Mismatch
8.1.3 Charge Pump Output Current Magnitude Variation Vs. Ambient Temperature
26 Submit Documentation Feedback Copyright © 2013–2015, Texas Instruments Incorporated
Product Folder Links: LMK04821 LMK04826 LMK04828

Table of Contents

Other manuals for Texas Instruments LMK04828

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Texas Instruments LMK04828 and is the answer not in the manual?

Texas Instruments LMK04828 Specifications

General IconGeneral
BrandTexas Instruments
ModelLMK04828
CategoryMotherboard
LanguageEnglish

Related product manuals