- 135 -
6.3.15 FEED COMMAND [ESC] T
Function Feeds the paper.
Format [ESC] Tabcde [LF] [NUL]
Term a: Type of sensor
0: No sensor
1: Reflective sensor
2: Transmissive sensor (when using normal labels)
3: Transmissive sensor (when using normal labels)
4: Reflective sensor
b: Selects cut or non-cut
0: Non-cut
1: Cut
c: Feed mode
C: Batch mode (Cut and feed when “Cut” is selected for parameter b.)
D: Strip mode (with back feed)
E: Strip mode (Reserved for future)
F: Partial cut mode (Non back feed cut mode)
d: Feedspeed
1: 2 inches/sec (2 inches/sec for the 300 dpi model)
2: 2 inches/sec (2 inches/sec for the 300 dpi model)
3: 3 inches/sec (3 inches/sec for the 300 dpi model)
4: 4 inches/sec (4 inches/sec for the 300 dpi model)
5: 5 inches/sec (4 inches/sec for the 300 dpi model)
6: 5 inches/sec (4 inches/sec for the 300 dpi model)
7: 5 inches/sec (4 inches/sec for the 300 dpi model)
8: 5 inches/sec (4 inches/sec for the 300 dpi model)
9: 5 inches/sec (4 inches/sec for the 300 dpi model)
A: 5 inches/sec (4 inches/sec for the 300 dpi model)
B: 5 inches/sec. (4 inches/sec for the 300 dpi model)
e: With/without ribbon
Direct thermal models:
Set to 0. (If “1” or “2” is specified, a ribbon error results.)
Thermal transfer models:
0: Without ribbon
1: With ribbon
2: With ribbon
Explanation (1) Type of sensor
c No sensor:
Media feed takes place according to the parameter designated by the Label
Size Set Command.
Note: When the “F: Partial cut mode” is designated for the feed mode, “No
sensor” should be selected. (The partial cutter is supposed to be used for
cutting continuous media, like receipt rolls.)