EasyManuals Logo
Home>Toshiba>Laptop>Qosmio F60 Series

Toshiba Qosmio F60 Series Maintenance Manual

Toshiba Qosmio F60 Series
466 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #56 background imageLoading...
Page #56 background image
Troubleshooting Procedures
2.3.2 Procedure 2 Error Code Check
If the power supply microprocessor detects a malfunction, the DC IN icon blinks orange. The
blink pattern indicates an error as shown below.
Start Off for 2 seconds
Error code (8 bit)
“1” On for one second
“0” On for half second
Interval between data bits Off for half second
The error code begins with the least significant digit.
Example: Error code 11h (Error codes are given in hexadecimal format.)
Start
Qosmio F60 Series Maintenance Manual (960-796) [CONFIDENTIAL] 2-15

Table of Contents

Other manuals for Toshiba Qosmio F60 Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Toshiba Qosmio F60 Series and is the answer not in the manual?

Toshiba Qosmio F60 Series Specifications

General IconGeneral
BrandToshiba
ModelQosmio F60 Series
CategoryLaptop
LanguageEnglish

Related product manuals