Signal setting:
Related parameter setting:
The quantity pass the Z phase signal after leaving the limit switch
The speed hitting the proximity switch
The speed leaving the proximity switch
Detailed explanation:
Find reference origin diagram:
Mode 3: internal speed
selecting signal
Range: 0000-0014, distributes to
input terminal through P5-28.
When it set to 0001, it means
input signal from SI1.
Mode 5/6: find origin point
at forward direction
Mode 3: internal speed
selecting signal
Range: 0000-0014, distributes to
input terminal through P5-29.
When it set to 0001, it means
input signal from SI1.
Mode 5/6: find origin point
at forward direction
Reference origin
of forward side
Reference origin
of reverse side