0: no parity, 1: odd parity, 2: even parity
Note: data bit cannot change, it is 8 bits
P7-02 RS485 communication protocol setting:
RS485 communication
protocol
(1) support standard Modbus RTU protocol, used as Modbus RTU slave device.
(2) RS232 and RS485 port can be used at the same time.
5-13-2. Battery using and changing
The battery can keep the absolute encoder position information when servo power is off. When the
servo drive power on again, the upper controller can read the motor encoder present position through
Modbus communication.
Battery specification: 3.6V No.5 type battery
The servo drive will show E- absolute encoder low battery alarm when the battery voltage is under
2.7V.
Note: if the battery voltage is low, the absolute encoder data will lose when the servo power on again.
The steps to change the battery:
(1) Please change the battery when the servo is power on, otherwise the absolute encoder
information will lose.
(2) After changing the battery, please restart the servo drive to delete the low battery alarm.
5-14.Internal position mode (only for DS3E/DS3L)
Internal position given mode
Internal 1~35 segment position parameters
Change the step signal /CHGSTP
Pause current signal /INHIBIT
Skip current signal /Z-CLAMP
The quantity pass through the Z phase signal after