20
9
8
13
U-
10
15
15
W-
11
1
1
Connect
to shield
layer
12
3
3
GND
13
2
2
5V
14
10
11
V+
15
12
14
V-
3-1-1-5. Communication port
RS-232 communication
(5-pin port)
Pin no.
Name
Explanation
1
TXD
RS232 send
2
RXD
RS232 receive
3
GND
RS232 ground
Note: please use the cable supplied by XINJE Company
Communication parameters:
RS232 default communication parameters: baud rate 19200bps, data bit 8, stop bit 1, even parity.
Modbus station no. setting:
Parameter
Function
Default
setting
Range
Modify
Effective
P7-10
Modbus station no.
1
1~255
Servo OFF
At once
Please set the following parameters through P7-11:
Parameter
no.
Function
Default
value
Range
Effective
time
n.xx□□
Baud rate
06
0010
00300
01600
021200
032400
044800
059600
0619200
0738400
0857600
09115200
At once
1
5

Table of Contents

Other manuals for Xinje DS3 Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Xinje DS3 Series and is the answer not in the manual?

Xinje DS3 Series Specifications

General IconGeneral
BrandXinje
ModelDS3 Series
CategoryServo Drives
LanguageEnglish

Related product manuals