8 Alarm Information
DS3 series alarm code format is E-XX□, XX is main category, □ is sub categories.
Hardware version
not match
The hardware version
is error
2. hardware damaged
3. external interference
is too serious
Parameter
self-checking cannot
pass
Re-power the servo to restore
default setting or contact us
The setting value out
of range
Check the parameters and set
again
TREF or VREF
function setting
conflict
Check the TREF or VREF setting
Sampling channel
setting error
User-defined output
trigger channel or data
monitor channel
setting error
Check the setting parameter
Power supply voltage
too low
1.for single phase 220V, connect
L1, L3
2. power on at once after cut
power supply it will show E-024
3. set the parameter again
Parameter store error
when power off
Flash chip power
supply not stable
(220V: U0-05 ≥
390 alarm,
380V: U0-05 ≥
780V alarm)
power grid voltage too
high
Check the power supply, 220V
servo drive voltage range is
200V~240V, 380V servo drive
voltage range is 360~420V, please
use regulator and correct power
supply
Load inertia too large
(regenerative ability
not enough)
1. connect external regenerative
resistor, please see below table for
resistor value (220V: bus voltage
U0-05=380 start discharging,
U0-05=350V discharge end.