124
8 Alarm Information
DS3 series alarm code format is E-XX, XX is main category, is sub categories.
XX
Alarm
Explanation
Reasons
Solution
01
0
E-010
Hardware version
not match
The hardware version
is error
Contact us
2
E-012
System loading
error
The program damaged
Contact us
3
E-013
FPGA loading
error
1. program damaged
2. hardware damaged
Contact us
4
E-014
FPGA visiting
error
1. program damaged
2. hardware damaged
3. external interference
is too serious
Contact us
5
E-015
Program running
error
Program damaged
Contact us
6
E-016
CPU running error
Hardware damaged
Contact us
7
E-017
CPU running
overtime
Program damaged
Contact us
8
E-018
FPGA running
overtime
Program damaged
Contact us
9
E-019
System password
error
Program damaged
Contact us
02
0
E-020
Parameter loading
error
Parameter
self-checking cannot
pass
Re-power the servo to restore
default setting or contact us
1
E-021
Parameter out of
range
The setting value out
of range
Check the parameters and set
again
2
E-022
Parameter conflict
TREF or VREF
function setting
conflict
Check the TREF or VREF setting
3
E-023
Sampling channel
setting error
User-defined output
trigger channel or data
monitor channel
setting error
Check the setting parameter
4
E-024
Parameter lost
Power supply voltage
too low
1.for single phase 220V, connect
L1, L3
2. power on at once after cut
power supply it will show E-024
3. set the parameter again
5
E-025
Erase flash error
Parameter store error
when power off
Contact us
6
E-026
Initialize flash
error
Flash chip power
supply not stable
Contact us
03
0
E-030
Bus overvoltage
(220V: U0-05
390 alarm,
380V: U0-05
780V alarm)
power grid voltage too
high
Check the power supply, 220V
servo drive voltage range is
200V~240V, 380V servo drive
voltage range is 360~420V, please
use regulator and correct power
supply
Load inertia too large
(regenerative ability
not enough)
1. connect external regenerative
resistor, please see below table for
resistor value (220V: bus voltage
U0-05=380 start discharging,
U0-05=350V discharge end.

Table of Contents

Other manuals for Xinje DS3 Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Xinje DS3 Series and is the answer not in the manual?

Xinje DS3 Series Specifications

General IconGeneral
BrandXinje
ModelDS3 Series
CategoryServo Drives
LanguageEnglish

Related product manuals