23
DS3-4□P□-PQA
PLC, SCM, etc servo drive
To avoid the interference, please use shielded twisted-pair cable.
(1) Servo pulse input will be ON at 10mA.
(2) If the controller is XINJE PLC, pulse output rated current is 50mA, so 1 channel of pulse can
connect 5 servo drives. We suggest not over 3 servo drives.
3-1-2-2SI input signal
Please use relay or open collector transistor to connect. When using relay, please choose micro-current
relay. Otherwise, the contact will be not good.
Type
Input terminal
Function
Reference chapter
Digital input
SI1~SI5
Multi-functional input
5-12-1
Open collector (24V power supply)
Relay (24V power supply)
Upper device servo drive
Upper device servo drive
Note: the max allowable voltage and current of open collector output circuit:
Voltage: max DC30V
Current: max DC50mA
3-1-2-3. SO output signal
Type
Output
terminal
Function
Reference chapter
Optocoupler
output
SO1~SO3
Multiple functions output terminal
5-12-3
SI
+24V
+
COM2
Y2
0V
+24V
R=2.2KΩ
R=2.2KΩ
+24V
0V
Y2
COM2
+
+24V
SI
P+24V
PUL+
PUL-
P-
R=3.3K
DIR-
D-
R=3.3K
P+5V
D+5V
Shield layer
0V
D+24V
DIR+
When upper
device is 5V
differential
output, please
use this wiring
diagram. Please
note: P+24V
and D+24V
must be vacant.

Table of Contents

Other manuals for Xinje DS3 Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Xinje DS3 Series and is the answer not in the manual?

Xinje DS3 Series Specifications

General IconGeneral
BrandXinje
ModelDS3 Series
CategoryServo Drives
LanguageEnglish

Related product manuals