Note: the rising edge of P5-35 step change signal triggers each position (the rising edge
is invalid during operation).
1. When the servo enable is off during a certain section of operation, the motor stops
according to the servo off shutdown mode. After the shutdown, the positioning is
invalid.
2. The adjustment time is not valid in this mode.
3. After each operation completion, positioning completion and positioning approach
signal are all effective.
4. After the segment number is selected, the rising edge of P5-35/CHGSTP step change
signal is required to trigger to run the position segment, and the step change triggering
during segment operation is invalid.
5. Segment number selection terminal logic is voltage level valid. Input high voltage
level is valid, input low voltage level is invalid.
3. Positioning mode