Parameters 107
01.30 Nominal torque scale Nominal torque in N•m which corresponds to 100%.
Note: This parameter is copied from parameter 99.12
Motor nominal torque if given. Otherwise the
value is calculated from other motor data.
0
0.000…4000000
N·m or lb·ft
Nominal torque. 1 = 100 unit
01.50 Current hour kWh Current hour energy consumption. This is the energy of
the last 60 minutes (not necessarily continuous) the drive
has been running, not the energy of a calendar hour. The
value is set to the value before the power cycle when the
drive is again up and running.
- / -
0.00…1000000.00
kWh
Energy. 1 = 1 kWh
01.51 Previous hour kWh Previous hour energy consumption. The value Current
hour kWh is stored here when its values has been
cumulated for 60 minutes. The value is set to the value
before the power cycle when the drive is again up and
running.
-
0.00…1000000.00
kWh
Energy. 1 = 1 kWh
01.52 Current day kWh Current day energy consumption. This is the energy of the
last 24 hours (not necessarily continuous) the drive has
been running, not the energy of a calendar day. The value
is set to the value before the power cycle when the drive is
again up and running.
-
0.00…1000000.00
kWh
Energy. 1 = 1 kWh
01.53 Previous day kWh Previous day energy consumption. The value is set to the
value before the power cycle when the drive is again up
and running.
-
0.00 … 1000000.00
kWh
Energy. 1 = 1 kWh
01.61 Abs motor speed used Absolute value of the motor speed used 01.01 Motor
speed used.
-
0.00… 30000.00 rpm 1 = 1 rpm
01.62 Abs motor speed % Absolute value of the motor speed % 01.03 Motor speed
%
-
0.00… 1000.00% 10 = 1%
01.63 Abs output frequency Absolute value of the output frequency 01.06 Output
frequency
-
0.00…500.00 Hz 1 = 1 Hz
01.64 Abs motor torque Absolute value of the motor torque 01.10 Motor torque.-
0.0...1600.0% 1 = 1%
01.65 Abs output power Absolute value of the output power 01.14 Output power.-
0.00...32767.00 kW or
hp
1 = 1 kW
01.66 Abs output power %
mot nom
Absolute value of the output power % of motor nominal
01.15 Output power % of motor nom.
-
0.00… 300.00% 1 = 1%
No. Name/Value Description Default