Parameters 173
15.41 AI2 actual value (Visible when 15.01 Module 2 type = FIO-11 or FAIO-01)
See parameter 14.41 AI2 actual value.
-
15.42 AI2 scaled value (Visible when 15.01 Module 2 type = FIO-11 or FAIO-0 1)
See parameter 14.42 AI2 scaled value.
-
15.43 AI2 force data (Visible when 15.01 Module 2 type = FIO-11 or FAIO-01)
See parameter 14.43 AI2 force data.
0.000 mA
15.44 AI2 HW switch
position
(Visible when 15.01 Module 2 type = FIO-11 or FAIO-01)
See parameter 14.44 AI2 HW switch pos.
-
15.45 AI2 unit selection (Visible when 15.01 Module 2 type = FIO-11 or FAIO-0 1)
See parameter 14.45 AI2 unit selection.
mA
15.46 AI2 filter gain (Visible when 15.01 Module 2 type = FIO-11 or FAIO-01)
See parameter 14.46 AI2 filter gain.
1 ms
15.47 AI2 filter time (Visible when 15.01
Module 2 type = FIO-11 or FAIO-01)
See parameter 14.47 AI2 filter time.
0.100 s
15.48 AI2 min (Visible when 15.01 Module 2 type = FIO-11 or FAIO-01)
See parameter 14.48 AI2 min.
0.000 mA or V
15.49 AI2 max (Visible when 15.01 Module 2 type = FIO-11 or FAIO-01)
See parameter 14.49 AI2 max.
10.000 mA or
V
15.50 AI2 scaled at AI2 min (Visible when 15.01 Module 2 type = FIO-11 or FAIO-0 1)
See parameter 14.50 AI2 scaled at AI2 min.
0.000
15.51 AI2 scaled at AI2 max (Visible when 15.01 Module 2 type = FIO-11 or FAIO-01)
See parameter 14.51 AI2 scaled at AI2 max.
100.000
15.56 AI3 actual value (Visible when 15.01 Module 2 type = FIO-11)
See parameter 14.56 AI3 actual value.
-
15.57 AI3 scaled value (Visible when 15.01 Module 2 type = FIO-11)
See parameter 14.57
AI3 scaled value.
-
15.58 AI3 force data (Visible when 15.01 Module 2 type = FIO-11)
See parameter 14.58 AI3 force data.
0.000 mA
15.59 AI3 HW switch
position
(Visible when 15.01 Module 2 type = FIO-11)
See parameter 14.59 AI3 HW switch pos.
-
15.60 AI3 unit selection (Visible when 15.01 Module 2 type = FIO-11)
See parameter 14.60 AI3 unit selection.
mA
15.61 AI3 filter gain (Visible when 15.01 Module 2 type = FIO-11)
See parameter 14.61 AI3 filter gain.
1 ms
15.62 AI3 filter time (Visible when 15.01 Module 2 type = FIO-11)
See parameter 14.62 AI3 filter time.
0.100 s
15.63 AI3 min (Visible when 15.01 Module 2 type = FIO-11)
See parameter 14.63 AI3 min.
0.000 mA or V
15.64 AI3 max (Visible when 15.01 Module 2 type = FIO-11)
See parameter 14.64 AI3 max
.
10.000 mA or
V
15.65 AI3 scaled at AI3 min (Visible when 15.01 Module 2 type = FIO-11)
See parameter 14.65 AI3 scaled at AI3 min.
0.000
15.66 AI3 scaled at AI3 max (Visible when 15.01 Module 2 type = FIO-11)
See parameter 14.66 AI3 scaled at AI3 max.
100.000
15.71 AO force selection (Visible when 15.01 Module 2 type = FIO-11 or FAIO-01)
See parameter 14.71 AO force selection.
00b
No. Name/Value Description Def/
FbEq16

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the ABB ACS880 PCP and is the answer not in the manual?

ABB ACS880 PCP Specifications

General IconGeneral
Output currentUp to 5200 A
Input voltage380-690 V
Power range5600 kW
Cooling methodAir or liquid
Protection classIP21, IP54
Communication interfacesEthernet, CANopen