DCS500 Pin and Parameter list
A 104
Group 119: REFERENCE SOURCES
CONST_REF:OUT
Signal of CONST_REF-function block ( S4/16 )
Selected constant speed reference.
11901 FB_O: I2 SC: SPEED HL: - LL: - D: - U: rpm
CONST_REF:ACT
Signal of CONST_REF-function block ( S4/16 )
Signal which is set to TRUE when one of the ACT-inputs is active.
11902 FB_O: B SC: BO HL: - LL: - D: - U: -
REF_SEL:OUT
Signal of REF_SEL-function block ( S4/16 )
Selected speed reference which is usually connected to the ramp generator input.
11903 FB_O: I2 SC: SPEED HL: - LL: - D: - U: rpm
SOFT_POT:OUT
Signal of SOFT_POT-function block ( S4/16 )
Speed reference from the software potentiometer.
11904 FB_O: I2 SC: SPEED HL: - LL: - D: - U: rpm
SOFT_POT:ACT
Signal of SOFT_POT-function block ( S4/16 )
Signal which is set to TRUE if either input SOFTPOT.[INCR] (1918) or SOFTPOT.[DECR]
(1919) is active.
11905 FB_O: B SC: BO HL: - LL: - D: - U: -