5.1.2 Calibration methods
Overview
This section specifies the different types of calibration and the calibration methods
that are supplied by ABB.
Types of calibration
Calibration methodDescriptionType of calibration
Axis Calibration or Cal-
ibration Pendulum
i
The calibrated robot is positioned at calibration
position.
Standard calibration data is found on the SMB
(serial measurement board) or EIB in the robot.
Standard calibration
For robots with RobotWare 5.04 or older, the
calibration data is delivered in a file, calib.cfg,
supplied with the robot at delivery. The file
identifies the correct resolver/motor position
corresponding to the robot home position.
CalibWareBased on standard calibration, and besides
positioning the robot at synchronization posi-
tion, the Absolute accuracy calibration also
compensates for:
• Mechanical tolerances in the robot
structure
• Deflection due to load
Absolute accuracy calibration focuses on pos-
itioning accuracy in the Cartesian coordinate
system for the robot.
Absolute accuracy
calibration (option-
al)
Absolute accuracy calibration data is found
on the SMB (serial measurement board) in the
robot.
For robots with RobotWare 5.05 or older, the
absolute accuracy calibration data is delivered
in a file, absacc.cfg, supplied with the robot at
delivery. The file replaces the calib.cfg file and
identifies motor positions as well as absolute
accuracy compensation parameters.
A robot calibrated with absolute accuracy has
a sticker next to the identification plate of the
robot.
To regain 100% absolute accuracy perform-
ance, the robot must be recalibrated for abso-
lute accuracy!
xx0400001197
i
The robot is calibrated by either Calibration Pendulum or Axis Calibration at factory. Always use
the same calibration method as used at the factory.
Information about valid calibration method is found on the calibration label or in the calibration
menu on the FlexPendant.
If no data is found related to standard calibration, Calibration Pendulum is used as default.
Continues on next page
392 Product manual - IRB 2600
3HAC035504-001 Revision: Q
© Copyright 2009-2018 ABB. All rights reserved.
5 Calibration
5.1.2 Calibration methods

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the ABB IRB 2600 Series and is the answer not in the manual?

ABB IRB 2600 Series Specifications

General IconGeneral
BrandABB
ModelIRB 2600 Series
CategoryRobotics
LanguageEnglish

Related product manuals