Refitting axis-6 motor and wrist unit
Use this procedure to refit the axis-6 motor and the wrist unit.
Refitting the motor
InformationAction
xx1000000929
Place the motor axis into the axis-6 flexible
coupling.
1
Parts:
A Attachment screws, bracket
B Flexible coupling
C Attachment screws, motor (3 pcs)
D Cylindrical pins (2 pcs)
E Motor axis 6
Tightening torque: 6 Nm.Secure the motor with its attachment
screws.
2
Tightening torque: 15 Nm.
xx1000000930
Secure the motor axis with the flexible
coupling with its attachment screw.
3
Parts:
A Attachment screw, coupling
B Flexible coupling
C Motor axis 6
Continues on next page
Product manual - IRB 2600 347
3HAC035504-001 Revision: Q
© Copyright 2009-2018 ABB. All rights reserved.
4 Repair
4.7.4 Replacing motor axis 6 and wrist unit - IRB 2600ID
Continued