3.3.8 Fault code 08.1.00 -
Fault code DIN brief description Cause Consequences Reference
08 = rear power lift (EPC)
0, 1, 2 = fault weighting (0 = heavy, 1 = medium; 2 = light)
01... = sequential number
The sorting of the error code is based on the serial number
08.1.00
Y184 [HKH] rear power lift control valve
Unknown rear EPC fault
08.1.05
A050 basic control unit ECU
Checksums/equipment parameters
incorrect
EOL
programming
08.1.06
A050 basic control unit ECU
Checksums/control parameters
incorrect
EOL
programming
08.1.07
A050 basic control unit ECU
Checksums/WSB parameters
incorrect
EOL
programming
08.1.0A
A050 basic control unit ECU
Implausible configuration EOL
programming
08.1.22
B145 rear power lift position sensor
Sensor faulty,
Signal fault
No control possible,
operable via external button
only
Circuit diagram
8.5 V supply A150, fuse 37
08.1.23
A100 MFA, multifunction armrest
Rear power lift setpoint value
potentiometer
Faulty setpoint value potentiometer
Signal fault
Setpoint values cannot be
set
Only position control
possible
08.1.24
X015 external control socket
Faulty external sensor, No control possible,
3. Faults and remedy
Maintenance 165
530.020.020.011 Rev.A

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the AGCO FENDT 1038 Vario S4 and is the answer not in the manual?

AGCO FENDT 1038 Vario S4 Specifications

General IconGeneral
BrandAGCO
ModelFENDT 1038 Vario S4
CategoryTractor
LanguageEnglish

Related product manuals