3.3.12 Fault code 0D.1.00 -
Fault
code
DIN brief description Cause Consequences Remedy
0D = VarioDoc
0, 1, 2 = fault weighting (0 = heavy, 1 = medium; 2 = light)
01... = sequential number
The sorting of the error code is based on the serial number
0D.1.00
A101 VarioDoc ECU
Unknown fault Restart system
0D.1.01
A103 NT01/02
terminal
CAN bus error (internal) Possible system failure
0D.1.02
A103 NT01/02
terminal
Serial connection cannot be established to the GSM modem GSM transfer not possible,
Internal serial interface module not
responding to internal GSM modem
0D.1.03
A103 NT01/02
terminal
K BUS fault,
K BUS CAN buffer (CAN 1) full: Possible break in the wiring,
loose contact or short circuit
Possible system failure
0D.1.05
A103 NT01/02
terminal
Excess temperature,
Internal temperature of control unit above 80°C
Possible system failure
0D.1.06
A101 VarioDoc ECU
Overvoltage,
Input voltage over 20 V
Possible system failure
0D.1.07
A101 VarioDoc ECU
Overcurrent,
Current input above 1 A
Possible internal short circuit
0D.1.08
A101 VarioDoc ECU
Error with GPS receiver power supply,
Short circuit in GPS receiver power supply
Meaningful system operation not
possible
3. Faults and remedy
190 Maintenance
530.020.020.011 Rev.A