316 Rockwell Automation Publication MOTION-RM003I-EN-P - February 2018
Feedback n Battery Absolute
Usage Access Data
Type
Default Min Max Semantics of Values
Optional - E
TM
Set/GSV USINT 0 - - Enumeration
0 = No
1 = Yes
The Feedback n Battery Absolute attribute determines if a battery is included in a
battery-backed absolute feedback device. This allows the drive to qualify Feedback
Battery Loss and Feedback Battery Low exception conditions.
See also
Feedback Attributes on page 302
General Feedback Info Attributes on page 316
General Feedback Signal Attributes on page 316
Interpreting the Attribute Tables on page 87
These are the general feedback information attributes associated with a Motion
Control Axis.
Feedback n Serial Number
Usage Access Data Type Default Min Max Semantics of Values
Optional - E Get
SHORT
STRING
- - - For example, 0012003400560078
The Feedback n Serial Number attribute is a 16-character string that specifies the
serial number of the device associated with Feedback n. If it is not possible for the
drive to read the Serial Number from the feedback device the drive sets this
attribute to a Null string.
See also
Feedback Attributes on page 302
General Feedback Signal Attributes on page 316
Feedback Configuration Attributes on page 304
These are the general feedback signal attributes associated with a Motion Control
Axis.
Attributes