EasyManuals Logo
Home>Allen-Bradley>Industrial Electrical>ControlLogix

Allen-Bradley ControlLogix Reference Manual

Allen-Bradley ControlLogix
497 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #453 background imageLoading...
Page #453 background image
CIP Axis Attributes
Chapter 4
Rockwell Automation Publication MOTION-RM003I-EN-P - February 2018 453
Power Loss Time
Usage Access T Data
Type
Default Min Max Semantics of Values
Optional - BD Set/SSV
REAL 0 0
Seconds
Sets the timeout value before a Bus Power Loss Exception is generated by the drive
in response to a Power Loss condition. For details, see the Power Loss Action
attribute table earlier in this topic.
See also
Motion Planner Configuration Attributes on page 367
State Behavior on page 61
These are the Start Inhibit related attributes associated with a Motion Control
Axis Object instance. Start Inhibits are conditions that prevent transition of the
motion axis from the Stopped State into any of the operational states.
CIP Start Inhibits
Usage Access T Data
Type
Default Min Max Semantics of Values
Required - D Get/GSV T WORD - - - Enumeration:
0 = Reserved
1 = Axis Enable Input
2 = Motor Not Configured
3 = Feedback Not Configured
4 = Commutation Not Configured
5 = Safe Torque Off Active
6 - 15 = Reserved
A bit map that specifies the current state of all standard conditions that inhibits
starting of the axis.
Start Inhibits Attributes

Table of Contents

Other manuals for Allen-Bradley ControlLogix

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Allen-Bradley ControlLogix and is the answer not in the manual?

Allen-Bradley ControlLogix Specifications

General IconGeneral
BrandAllen-Bradley
ModelControlLogix
CategoryIndustrial Electrical
LanguageEnglish

Related product manuals