FlexiROC T30 R 18 Water Mist System
125 No: 3629357835.1.3629419915 en-US
18 Water Mist System
NOTICE
Damage to Water Mist Pump
Risk of damage to water mist pump if it is run without water in the system.
u Do not run the pump without water in the system.
NOTICE
Risk of Damage to Water Mist System
During cold weather, the water in the water mist system can freeze and damage the
system when the machine is turned off for a prolonged period.
u Drain the water mist tank.
u Flush anti-freeze through the system.
NOTICE
Risk of Damage to DCT
When dust collecting in the DCT is damp or water starts flushing out of the drill hole,
hoses and filters in the DCT can clog.
u Switch off the dust collector if the dust is damp or if water starts flushing out of the drill
hole.
Water is pumped from a tank on the machine into the air circuit by a hydraulic-driven
pump. The pump is located in a compartment on top of the water tank. The water mist sys-
tem is not pressurized.