FlexiROC T30 R 15 Compressed Air System
99 No: 3629357835.1.3629419915 en-US
15 Compressed Air System
15.1 Check Compressor Oil Level
Precondition
p
The machine is parked on a flat and leveled surface.
1.
Switch off the machine and allow the oil level to settle for at least five minutes.
2.
Check the compressor oil level. The indicator on the gauge (A) must be in the green
zone.
3.
Fill with oil through inlet (B), if necessary. Use the correct amount and oil grade.
15.2 Oil Change and Oil Filter Replacement
Oil grade and operating temperature determines the intervals for oil change. The pre-
scribed interval is based on an oil temperature of up to 120 ºC (248 ºF) and normal operat-
ing conditions. Oil must be changed more frequently when working in high ambient temper-
atures or dusty or damp conditions.
The system must be flushed clean before new oil is filled if the oil is
n Contaminated by incorrect oil.
n Broken down due to excessive temperature.
n Used beyond the operating interval.