FlexiROC T30 R 13 Electrical System
95 No: 3629357835.1.3629419915 en-US
4.
Connect the battery charger's positive cable to the positive terminal on battery (A).
Connect the battery charger's negative cable to the negative terminal on battery (A).
5.
Start the battery charger.
6.
Turn off the battery charger when battery (A) is fully charged.
7.
Disconnect the battery charger's negative cable from the negative terminal on battery
(A). Disconnect the battery charger's positive cable from the positive terminal on bat-
tery (A).
8.
Connect the battery charger's positive cable to the positive terminal on battery (B).
Connect the battery charger's negative cable to the negative terminal on battery (B).
9.
Start the battery charger.
10.
Turn off the battery charger when battery (B) is fully charged.
11.
Disconnect the battery charger's negative cable from the negative terminal on battery
(B). Disconnect the battery charger's positive cable from the positive terminal on bat-
tery (B).
12.
Connect the jumper lead between the negative terminal on battery (B) and the posi-
tive terminal on battery (A).
13.
Connect the cable between chassis ground and the negative terminal on battery (A).
14.
Turn on battery isolation switch.
13.7 Starting with Auxiliary Battery
WARNING
Explosion Risk
There is a risk of personal injury if a fully-charged battery is connected to a discharged
battery.
u Use a well ventilated area.
u Fire-extinguisher must be close at hand.
u Use protective glasses.
u Use protective gloves.