FlexiROC T30 R 13 Electrical System
94 No: 3629357835.1.3629419915 en-US
3.
Connect the battery charger's positive cable to the battery's positive terminal (B).
Connect the battery charger's negative cable to the battery's negative terminal (A).
4.
Start the battery charger.
5.
Turn off the battery charger when batteries are fully charged.
6.
Disconnect the battery charger's negative cable from the battery's negative terminal
(A). Disconnect the battery charger's positive cable from the battery's positive terminal
(B).
7.
Connect the cable between chassis ground and the negative terminal on battery (A).
8.
Turn on battery isolation switch.
13.6 Charging Battery Using External 12V Charger
WARNING
Risk of Fire and Explosion
Gas that is formed in the battery during charging and dis-charging is explosive which
can cause serious personal injury and damage to property.
u Avoid open flames and sparks.
u Ensure good ventilation.
u Disconnect the negative terminal first, and connect it last.
u Disconnect the fire-fighting system.
u Use protective glasses.
u Use protective gloves.
Serial Connected 12V Batteries
1.
Turn off the battery isolation switch.
2.
Disconnect the cable between chassis ground and the negative terminal on battery
(A).
3.
Disconnect the jumper lead between the negative terminal on battery (B) and the pos-
itive terminal on battery (A).