31
71.07144.01 - EN
INSTRUCTIONS FOR USERS
10. TROUBLESHOOTING
Do not drain the whole system as lling up with water again causes unnecessary and harmful scale to build up inside the
boiler and the heating elements. If the boiler is not used during winter and is therefore exposed to the danger of frost, add
some specic anti-freeze to the water in the system (e.g.: propylene glycol coupled with corrosion and scale inhibitors). The
electronic boiler management system includes a “frost protection” function for the heating system which, when delivery
temperature falls below 5°C, operates the burner until a delivery temperature of 30°C is reached.
The frost protection function is enabled if:
* the boiler is electrically powered;
* the gas tap is open;
* the system is at the correct pressure;
* the boiler is not blocked.
9. PROLONGED SHUTDOWN. FROST PROTECTION
CODE
DISPLAYED
FAULT
CORRECTIVE ACTION
E01
Failed ignition shutdown
Press and hold down “R”. for at least 2 seconds. If this fault persists, call the Authorised
Service Centre.
E02
Safety thermostat tripped
Press and hold down “R”. for at least 2 seconds. If this fault persists, call the Authorised
Service Centre.
E03
Flue thermostat/ ue pressure switch
tripped
Call the Authorised Service Centre.
E04
Shutdown after 6 consecutive ame
losses
Press and hold down “R”. for at least 2 seconds. If this fault persists, call the
Authorised Service Centre.
E05
Delivery probe failure
Call the Authorised Service Centre.
E06
DHW sensor fault
Call the Authorised Service Centre.
E10
Hydraulic pressure switch block
Check that the pressure in the system is correct; See section 6. If this fault persists,
call the Authorised Service Centre.
E25/E26
No water circulation (probable blocked
pump).
Call the Authorised Service Centre.
E27 Wrong DHW sensor position
Press and hold down “R”. for at least 2 seconds. If this fault persists, call the Authorised
Service Centre.
E32
Limescale alarm
Call the Authorised Service Centre.
E35
Parasite ame (amer error)
Press and hold down “R”. for at least 2 seconds. If this fault persists, call the Authorised
Service Centre.
E96
Switching off due to reductions in the
power supply
RESET is automatic. If this fault persists, call the Authorised Service Centre.
NOTE
: in case of a fault, the display backlighting ashes together with the error code.
To keep the boiler efcient and safe, have it checked by the authorised Service Centre at the end of every operating period.
Careful servicing ensures economical operation of the system.
Do not clean the outer casing of the appliance with abrasive, aggressive and/or easily ammable cleaners (e.g.: petrol,
alcohol, and so on). Always switch off the appliance before cleaning it (see section 7 “Switching off the boiler”).
11. ROUTINE MAINTENANCE INSTRUCTIONS
Faults are shown on the display with an error code
(e.g.: E 01): To RESET the boiler, press and hold down
“R” for at least 2 seconds. If this fault persists, call the
Authorised Service Centre.
N.B.: 5 reset attempts can be performed after which
the boiler shuts down. To reset again, switch off the
boiler for a few seconds.
Figure 3
RESETTABLE faults
0607_1205