Do you have a question about the Chenbro RM23712 and is the answer not in the manual?
Brand | Chenbro |
---|---|
Model | RM23712 |
Category | Racks & Stands |
Language | English |
General overview of system features and available options.
Key features and component locations on the server board.
Description of buttons, LEDs, and ports on the front control panel.
Overview and scope of the power supply specification (FSP800-20ERM).
Detailed electrical specifications and performance criteria.
Specifications for AC input voltage, frequency, and connectors.
Maximum input current ratings for various input voltages.
Module efficiency requirements for 80Plus Platinum rating.
Immunity requirements for EMI, transients, surges, and ESD.
Immunity requirements against AC Ringwave and AC Unidirectional surges.
Performance during AC line sag and surge conditions.
Requirements for fast transient (EFT) immunity.
Specifications for DC output voltages and their regulation.
Power and current ratings for the +12V and +12Vsb outputs.
Voltage regulation requirements for output voltages under various conditions.
Specifications for output ripple and noise levels.
Requirements for step loading and capacitive loading.
Active load sharing capabilities for parallel power supplies.
Timing requirements for power supply operation and turn-on/off signals.
Timing specifications for output voltage rise and fall.
Input and output signals for power supply control and status indication.
Description of the PSON# signal for remote power on/off control.
Description of the Power Good (PWOK) signal indicating output status.
Overview of internal protection circuits like OVP, OCP, and OTP.
Protection against over-voltage conditions on main and auxiliary outputs.
Protection against over-current and short-circuit conditions.
Protection against over-temperature conditions.
Detection and handling of power supply internal fan failures.
Features related to power supply management and communication.
Details on PSMC compatibility, addresses, and related documents.
Guidelines for operating within maximum thermal limits and configuration.
Components and strategies for maintaining airflow and system cooling.
BMC support for monitoring and controlling fan speed (RPM).
Using IPMI sensors as input for fan speed control algorithms.
Web server and GUI for BMC manageability, including supported browsers.
Features enabled by the optional Intel RMM4 Lite module, including KVM.
Remote KVM access and control over LAN for server management.
Functionality and requirements for the Remote Console Java applet.
Mounting remote IDE, USB CD-ROM, floppy, or USB flash disk as remote devices.