EasyManuals Logo
Home>Cisco>Switch>WS-C3750-48PS-S

Cisco WS-C3750-48PS-S User Manual

Cisco WS-C3750-48PS-S
1010 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #579 background imageLoading...
Page #579 background image
30-15
Catalyst 3750 Switch Software Configuration Guide
78-16180-02
Chapter 30 Configuring SNMP
Configuring SNMP
The snmp-server host command specifies which hosts receive the notifications. The snmp-server
enable trap command globally enables the mechanism for the specified notification (for traps and
informs). To enable a host to receive an inform, you must configure an snmp-server host informs
command for the host and globally enable informs by using the snmp-server enable traps command.
To remove the specified host from receiving traps, use the no snmp-server host host global
configuration command. The no snmp-server host command with no keywords disables traps, but not
informs, to the host. To disable informs, use the no snmp-server host informs global configuration
command. To disable a specific trap type, use the no snmp-server enable traps notification-types global
configuration command.
Setting the Agent Contact and Location Information
Beginning in privileged EXEC mode, follow these steps to set the system contact and location of the
SNMP agent so that these descriptions can be accessed through the configuration file:
Step 9
snmp-server trap-timeout seconds (Optional) Define how often to resend trap messages. The range is 1 to
1000; the default is 30 seconds.
Step 10
end Return to privileged EXEC mode.
Step 11
show running-config Verify your entries.
Step 12
copy running-config startup-config (Optional) Save your entries in the configuration file.
Command Purpose
Command Purpose
Step 1
configure terminal Enter global configuration mode.
Step 2
snmp-server contact text Set the system contact string.
For example:
snmp-server contact Dial System Operator at beeper 21555.
Step 3
snmp-server location text Set the system location string.
For example:
snmp-server location Building 3/Room 222
Step 4
end Return to privileged EXEC mode.
Step 5
show running-config Verify your entries.
Step 6
copy running-config startup-config (Optional) Save your entries in the configuration file.