Page #328 background image
SA Indoor Unit - FFQ, FCQ, FDBQ, FBQ, FHQ Series SiBE18-821_C
316 Operation Manual
English 8
ON/OFF
Press ON/OFF button
NOTE
2
TEMPERATURE SETTING
In case of automatic operation
[°C]
The setting is impossible for fan operation.
NOTE
ADJUSTMENT
HM••L
25 23 22 21 19
FAN OPERATION......................
DRY OPERATION..................... “
See “FOR SYSTEMS WITHOUT COOL/
HEAT CHANGEOVER REMOTE CONTROL
SWITCH” for details on dry operation.
(2)
Press OPERATION MODE SELECTOR
button several times and select “
(
This operation is only available during
dry operation.)
OPERATION lamp lights up or goes off and
the system starts or stops OPERATION.
Do not turn OFF power immediately
after the unit stops. Then, wait no less
than 5 minutes.
Water is leaking or there is something
else wrong with the unit.
[EXPLANATION OF HEATING
OPERATION]
DEFROST OPERATION
As the frost on the coil of an outdoor
unit increase, heating effect decreases
and the system goes into DEFROST
OPERATION.
The fan operation stops and the
DEFROST lamp of the indoor unit goes
on. After 6 to 8 minutes (maximum 10
minutes) of DEFROST OPERATION, the
system returns to HEATING OPERATION.
Heating capacity & Outdoor air
temperature
Heating capacity drops as outdoor air
temperature lowers. If feeling cold, use
another heater at the same time as this
air conditioner.
Hot air is circulated to warm the room. It
will take some time from when the air
conditioner is first started until the entire
room becomes warm. The internal fan
automatically turns at low speed until the
air conditioner reaches a certain
temperature on the inside. In this
situation, all you can do is wait.
If hot air accumulates on the ceiling and
feet are left feeling cold, it is
recommended to use a circulator. For
details, contact the place of purchase.
For programming TEMPERATURE, FAN
SPEED and AIR FLOW DIRECTION, follow
the procedure shown below.
Press TEMPERATURE SETTING
button and program the setting
temperature
Each time this button is pressed,
setting temperature rises 1°C.
Each time this button is pressed,
setting temperature lowers 1°C.
Each time this button is pressed,
setting temperature shifts to “H”
side.
Each time this button is pressed,
setting temperature shifts to “L”
side.
Setting
temperature
The setting temperature range of the
remote controller is 16˚C to 32˚C.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Daikin Super Multi Plus E-Series FFQ50B8V1B and is the answer not in the manual?

Daikin Super Multi Plus E-Series FFQ50B8V1B Specifications

General IconGeneral
BrandDaikin
ModelSuper Multi Plus E-Series FFQ50B8V1B
CategoryAir Conditioner
LanguageEnglish

Related product manuals