84 Printer Manager
 Hopper1CardStockLoaded—The card stock loaded in the input hopper.
 RetransferCoolTime—The time, in milliseconds, to allow the card to cool after the retransfer
completes.
 RetransferLaminationSpeed—The speed at which to apply the retransfer film to side 1 of the
card for the card stock specified in CardStockDisplayed.
 RetransferLaminationSpeedLayer2—The speed at which to apply the second layer of
retransfer film to side 1 of the card. The setting applies to the card stock specified in
CardStockDisplayed.
 RetransferLaminationSpeedLayer2Side2—The speed at which to apply the second layer of
retransfer film to side 2 of the card. The setting applies to the card stock specified in
CardStockDisplayed.
 RetransferLaminationSpeedSide2—The speed at which to apply the retransfer film to side 2
of the card if the card design does not include inhibitor or smart card programming. The
setting applies to the card stock specified in CardStockDisplayed.
 RetransferRollerTemp—The temperature (in degrees Celsius) of the heated roller when
applying the retransfer film to side 1 of the card stock specified in CardStockDisplayed. The
heated roller remains at the specified temperature.
 RetransferRollerTempSide2—The temperature (in degrees Celsius) of the heated roller when
applying the retransfer film to side 2 of the card stock specified in CardStockDisplayed. The
heated roller remains at the specified temperature.
HeatRoller
The HeatRoller setting specifies the time the printer is idle before power to the heated roller is
turned off.
Change setting as needed, and then click Set Current to apply changes.
 HeaterMinutesToPowerSave—Set the number of minutes of idle time before the heated
roller is turned off. After waiting the specified number of minutes, the roller is allowed to
cool down. A value of 0 allows the roller to start cooling down immediately.
Using power save requires a brief warm-up period before the printer is ready to print cards
again. The front panel LCD displays the message Busy Warming up and a percentage that
indicates the status of the heated roller.
Description Default Value
Current Value
(unit) Allowed Range
1) HeaterMinutesToPowerSave 15 15 [0 – 240]

Table of Contents

Other manuals for DataCard CR805

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the DataCard CR805 and is the answer not in the manual?

DataCard CR805 Specifications

General IconGeneral
BrandDataCard
ModelCR805
CategoryPrinter
LanguageEnglish

Related product manuals