5 Before installation
5.1 Installation regulations
Warning
The boiler must be installed by a qualified installer in accordance
with local and national regulations.
5.2
Choice of the location
5.2.1 Data plate
The data plate on top of the boiler states the boiler serial number and
important boiler specifications such as the model and gas category. The
configuration numbers CN1 and CN2 codes are also stated on the data
plate.
5.2.2 Location of the boiler
Use the guidelines and the required installation space as a basis for
determining the correct place to install the boiler.
When determining the correct installation area, take account of the
permitted position of the flue gas outlet and/or air supply outlet.
Ensure that there is sufficient space around the boiler for good access
and ease of maintenance.
Mount the boiler onto a flat surface.
Danger
It is forbidden to store, even temporarily, combustible products
and substances in the boiler or near the boiler.
Warning
Fix the appliance to a solid wall capable of bearing the weight of
the boiler when full of water and fully equipped.
Do not place the appliance above a heat source or a cooking
appliance.
Do not locate the boiler in direct or indirect sunlight.
Caution
The boiler must be installed in a frost-free area.
An earthed electrical connection must be available close to the
boiler.
A connection to the drain must be present for the condensate
drain close to the boiler.
Fig.11 Position of data plate
Fig.12 Installation area
AD-0001376-02
450
min.10
0
0
4
5
0
min.
250
m
i
n.
2
5
0
690