Power control procedures
Learn how to power down and power up the system.
Topics:
Power control procedure considerations
Power control procedures preview
Powering off procedures for PowerStore node
Powering on procedures for PowerStore node
Rebooting procedures for a PowerStore node
Powering off procedures for PowerStore appliances
Powering on procedures for PowerStore appliances
Powering off procedures for PowerStore cluster
Powering on procedures for PowerStore cluster
Power control procedure considerations
Note the following before you get started:
Powering off a node, appliance, or cluster can take several minutes to complete.
In a true emergency power off situation, turn the cabinet power switches to the off position to immediately remove power from the all
cabinet components.
Working with hardware may cause electrostatic discharge that could damage your hardware. Before working with any hardware, take
precautions around handling replaceable units.
If you are relocating or replacing hardware, to help identifying associated enclosures when you are ready to cable and power on:
Ensure that you make a note of the cabling between enclosures and the appliances. If you used cable labels at the time of initial
installation, reconnecting the cables will be easier.
Ensure that you also record the Dell service tag numbers of all enclosures in your cluster.
Nodes in the appliance power on in the same mode that they were in when the appliance was powered off. If a node powers on in
service mode:
1. Log in to the appliance from an SSH client.
2. Run the svc_rescue_state clear command to clear the boot mode.
3. Then, run the svc_node reboot command to reboot the node and return it to normal mode.
For more information about the service scripts, see the PowerStore Service Scripts Guide.
If both nodes in an appliance reboot in service mode, always return Node A to normal mode first to avoid management software
conflicts. After Node A is operating normally, you can return Node B to normal mode.
A PowerStore X model appliance consists of two ESXi host nodes (node A and node B), running VMware ESXi version 6.7, and a
controller VM on each that runs the PowerStore operating environment. Powering off a PowerStore X model node, appliance, or
cluster requires operations in the associated VMware vCenter server. See the VMware documentation for more information about the
vCenter server commands.
Power control procedures preview
The following table provides a preview of the steps that are required to power off or up the relevant component in your cluster:
Table 5. Power control procedures preview
Component Action PowerStore T model PowerStore X model
Node Power off Use PowerStore Manager.
Or
Run a service script.
Use VMware vCenter server.
C
Power control procedures 101