18
6 DIAGNOSTICS SYSTEM
6.1 Accessing diagnostics
The operations listed below must be carried out within 7 seconds.
Do not start the machine with this combination of buttons pressed, only when accessing
diagnostic mode
1. Switch on the appliance using the ON/OFF button. The first LED in the right hand row will light up.
2. Press the START/PAUSE button and the nearest option button simultaneously (as shown in the
figure).
3. Hold the buttons/sensors down/pressed until the LEDs and symbols begin to flash in sequence
(approximately 3 seconds).
In the first position, the operation of the buttons, of the related LEDs and of the groups of symbols shown
on the LCD screen is checked; turn the programme selector dial clockwise to run the diagnostic cycle for
the operation of the various components and to read any alarms (see diagnostic testing on the following
page).
During this phase, if any key combination is pressed (except for the one relating to diagnostics), all the
combinations of options stored are deleted (Extra rinse, No buzzer, etc..).
6.2 Quitting the diagnostics system
To exit the diagnostic cycle, switch the appliance off, then back on and then off again.