144 ADV200 • Quick start up guide
9.7.2 Overload for output frequency
Sizes
For Asynchronous motors
Heavy duty Light duty
K1 SP [%] K2 SP [Hz] K3 SP [Hz] K1 SL [%] K2 SL [Hz]
1007 100 3 4.8 100 3
1015 100 3 4.8 75 3
1022 100 3 4.8 75 3
1030 100 3 4.8 80 3
1040 100 3 4.8 100 3
2055 100 3 4.8 100 3
2075 100 3 4.8 75 3
2110 100 3 4.8 75 5
3150 100 5 8 75 7
3185 100 5 8 85 5
3220 100 3 4.8 80 5
4300 100 3 4.8 80 3
4370 100 3 4.8 80 3
4450 100 3 4.8 80 3
5550 100 3 4.8 85 5
5750 100 5 8 85 5
5900 100 5 8 85 5
61100 100 3 4.8 100 3
61320 100 3 4.8 100 3
71600 100 3 4.8 80 3
72000 100 3 4.8 100 3
72500 100 3 4.8 75 5
73150 100 3 4.8 100 3
73551 100 3 4.8 100 3
400 kW 100 3 4.8 100 3
500 kW 100 3 4.8 75 5
630 kW 100 3 4.8 100 3
710 kW 100 3 4.8 100 3
900 kW 100 3 4.8 100 3
1 MW 100 3 4.8 100 3
Figure 9.7.2.1: HD Overload (For Asynchronous motors) Figure 9.7.2.2: LD Overload (For Asynchronous motors)
70
80
90
100
110
120
130
140
150
160
170
180
190
200
012345678
91
0
f [Hz]
I out [%]
k1
k2
k3
70
80
90
100
110
120
0123456789
10
f [Hz]
I out [%]
k1
k2
_ _ Islow, .... Ifast; __ I
n
_ _ Islow, __ I
n
Sizes
For Synchronous motors
Heavy duty Light duty
K1 SP [%] K2 SP [Hz] K3 SP [Hz] K1 SL [%] K2 SL [Hz]
1007 100 3 5 100 3
1015 100 3 5 75 3
1022 100 3 5 75 3
1030 100 3 5 80 3
1040 100 3 5 100 3
2055 100 3 5 100 3