ADV200 • Quick start up guide 169
10.4.3 Matching motors, RHF lters and ADV200 drives
Grid: 380V / 50Hz
Motor
Power 4
poles IE2
Motor
Efficiency
Drive
Size
Drive Output: Light Duty
RHF Passive Filter
Line Input
Current
@ 380V
Rated
Power
Rated
Current
Overload
Type (1) Current
[%] [kW] [A] [A] [A]
1.5 82.8 1007 1.5 4.3 RHF-A/B 6-400-50-20-A (3) 6 2.9
2.2 84.3 1015 2.2 5.8 RHF-A/B 6-400-50-20-A
(3) 6 4.1
3 85.5 1022 3 7.6 RHF-A/B 6-400-50-20-A 6 5.5
4 86.6 1030 4 9.5 RHF-A/B 10-400-50-20-A 10 7.3
5.5 87.7 1040 5.5 13 RHF-A/B 10-400-50-20-A 10 9.9
7.5 88.7 2055 7.5 16.5 RHF-A/B 14-400-50-20-A 14 13.3
11 89.8 2075 11 23 RHF-A/B 22-400-50-20-A 22 19.3
15 90.6 2110 15 31 RHF-A/B 29-400-50-20-A 29 26.1
18.5 91.2 3150 18.5 38 RHF-A/B 35-400-50-20-A 35 31.9
22 91.6 3185 22 46 RHF-A/B 35-400-50-20-A 35 37.8
30 92.3 3220 30 62 RHF-A/B 58-400-50-20-A 58 51.2
37 92.7 4300 37 75 RHF-A/B 58-400-50-20-A 58 62.8
45 93.1 4370 45 87 RHF-A/B 72-400-50-20-A 72 76.1
55 93.5 4450 55 105 RHF-A/B 86-400-50-20-A 86 92.6
75 94 5550 75 150 RHF-A/B 144-400-50-20-A 144 125.6
90 94.2 5750 90 180 RHF-A/B 144-400-50-20-A 144 150.4
110 94.5 5900 110 210 (2) RHF-A/B 180-400-50-20-A 180 183.2
132 94.7 61100 132 250 RHF-A/B 217-400-50-20-A 217 219.4
160 94.9 61320 160 300 RHF-A/B 252-400-50-20-A 252 265.4
200 95.1 71600 200 385 RHF-A/B 325-400-50-20-A 325 331.0
250 95.1 72000 250 460 RHF-A/B 433-400-50-20-A 433 413.8
315 95.1 72500 315 590 RHF-AS/BS 480-400-50-230-A 480 521.4
355 95.1 73150 355 650 RHF-AS/BS 550-400-50-230-A 550 587.6
400 95.5 73551 400 730 RHF-AS/BS 650-400-50-230-A 650 659.3
500 95.8 400 kW 500 870 RHF-AS/BS 850-400-50-230-A 850 821.5
630 96 500 kW 630 1120 RHF-AS/BS 980-400-50-230-A 980 1033.0
710 96.5 630 kW 710 1230 RHF-AS/BS 1090-400-50-230-A 1090 1158.1
800 96.7 710 kW 800 1380 RHF-AS/BS 1200-400-50-230-A 1200 1302.2
1000 96.7 900 kW 1000 1800 On request
1200 96.7 1 MW 1200 2050 On request
1500 96.7 1.35 MW 1650 2540 On request
1800 96.7 1.65 MW 1800 3100 On request
(1) RHF-A/B: RHF-A Models ... or RHF-B-... , RHF-AS/BS: RHF-AS Models ... or RHF-BS-...; see section 10.4.1.
(2) Overload 110% the Rated Current for 60s every 300s
(3) Reduced THDi performance due to part load
Grid: 400 - 415V / 50Hz
Motor
Power 4
poles IE2
Motor
Efficiency
Drive
Size
Drive Output: Light Duty
RHF Passive Filter
Line Input
Current
@ 400V
Rated
Power
Rated
Current
Overload
Type (1) Current
[%] [kW] [A] [A] [A]
1,5 82,8 1007 1,5 4,3 RHF-A/B 6-400-50-20-A (3) 6 2,7
2,2 84,3 1015 2,2 5,8 RHF-A/B 6-400-50-20-A
(3) 6 3,9
3 85,5 1022 3 7,6 RHF-A/B 6-400-50-20-A 6 5,2
4 86,6 1030 4 9,5 (2) RHF-A/B 10-400-50-20-A 10 6,9
5,5 87,7 1040 5,5 13 RHF-A/B 10-400-50-20-A 10 9,4
7,5 88,7 2055 7,5 16,5 RHF-A/B 14-400-50-20-A 14 12,6
11 89,8 2075 11 23 RHF-A/B 22-400-50-20-A 22 18,3
15 90,6 2110 15 31 RHF-A/B 29-400-50-20-A 29 24,8