XNX Universal Transmitter
Specications
156
Certifications by Part Number Series
Contact Honeywell Analytics for information about XNX
®
Universal Transmitter approvals not shown in this section.
XNX Certifications XNX-UT Series
XNX Part Number Series
XNX
Transmitter IR
Personality
XNX Transmitter mV Personality
XNX Transmitter EC
Personality
Options
XNX-UTSI-*****
XNX-UTAI-*****
XNX-UTSV-***** / XNX-UTAV-*****
XNX-UTSE-***** /
XNX-UTAE-*****
With Generic 20 mA Input
With Optima Plus
With Searchline Excel
MPD-UTCB1 (Cat Bead)
MPD-UTIV1 (IR Methane)
MPD-UTIF1 (IR Flam)
MPD-UTIC1 (IR CO
2
)
with 705
with Sensepoint
with Sensepoint PPM
with Sensepoint HT
With XNXXSO1FM O
2
Cartrdige
With XNXXSH1FM H
2
S Cartridge
With XNXXSC1FM CO Cartridge
SO
2
, NH
3
, Cl
2
, ClO
2
, NO, NO
2
, H
2
PPM, HCL, HF, PH
3
HCN, F
2
, O
3
, EtO
Modbus
®
Relays
Local HART
®
FOUNDATION™ Fieldbus
UL Listed
For Hazardous Locations
UL 1203 T T T T T T T T N/A N/A N/A T T T T T T T T T
UL 913-7th Edition N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A T T T T T N/A N/A T N/A
ISA 60079-29-1 N/A T N/A T N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A
CSA
Hazardous Location
CAN/CSA C22.2 No. 30 M-1986 T T T T N/A N/A T T N/A N/A N/A T T T T T T T T N/A
CAN/CSA C22.2 No. 157-92
(Applies to Local HART Option and/or
EC Adaptors)
N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A T T T T T N/A N/A T N/A
Performance CSA C22.2 No. 152 N/A T N/A T N/A N/A N/A T N/A N/A N/A N/A N/A N/A N/A N/A T T T T
FM Listed
US Toxic Performance Standard referenced in notes 1, 2, 3 N/A N/A N/A N/A N/A N/A 3 N/A N/A N/A N/A 1 2 3 N/A N/A T T T T
Flammable Performance
FM 6310 / 6320 N/A T N/A T N/A N/A N/A T N/A N/A N/A N/A N/A N/A N/A N/A T T T T
FM 6325 N/A N/A T N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A N/A T T T T
Toxic Gas Detector FM 6340 N/A N/A N/A N/A N/A N/A T N/A N/A N/A N/A N/A N/A N/A N/A N/A T T T T
T = 3/4 NPT threaded Transmitters & Adapters
N/A = Not Applicable
1. ANSI/ISA 92.04.01, Part 1 2007
2. ISA 92.0.01, Part 3 1998
3. FM 6340

Table of Contents

Other manuals for Honeywell XNX-UT Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Honeywell XNX-UT Series and is the answer not in the manual?

Honeywell XNX-UT Series Specifications

General IconGeneral
BrandHoneywell
ModelXNX-UT Series
CategoryTransmitter
LanguageEnglish

Related product manuals