XNX Universal Transmitter
Specications
167
Accessories/Spares
See publication 1998-0807 XNX Universal Transmitter Parts List for a description of the parts and accessories shipped with the transmitter.
Accessory Part Number Description
Pipe Mount Kit 1226A0358
For use on pipes from 2-6 inches (50-150mm) in diameter. The kit includes a pipe
mount bracket, 2 carriage bolts, nuts and lock washers.
Remote EC Sensor
Mounting Kit
S3KRMK
S3KRMK45
S3KRMK75
The remote sensor mounting kits (S3KRMK45 and S3KRMK75) allows the XNX EC
sensors to be remotely mounted via an IS cable kit from the transmitter. A choice of
cable lengths are available - 50 feet (15 meters), 148 feet (45 meters) or 246 feet (75
meters) and all are supplied with cable glands and remote terminal box. The cable can
be cut to the required length and terminated at the remote terminal box. (It cannot be
extended or spliced.)
Ceiling Mount
Bracket Kit
1226A0355
The optional Ceiling Mount Bracket Kit allows the XNX to be mounted to the ceiling.
The kit includes two stainless steel ceiling mount brackets and the necessary bolts
and nuts.
Duct Mount Kit S3KDMK
The duct mounting kit (S3KDMK) can be used with the EC sensor to allow detection of
O2, CO, H2 and H2S gases in ducts.
When combined with the MPD Interface Adapter (1226A0382), the duct mounting
kit can accommodate the MPD to detect ammable gases in a duct application.
The duct mount kit includes the adapter, gasket and required fasteners. The MPD
Interface Adapter includes only the adapter and requires the S3KDMK duct mount kit.
MPD Interface
Adaptor
1226A0382
Calibration Gas Flow
Adaptor
S3KCAL EC
1226A0411 MPD
00780-A-0035 Sensepoint HT
00780-A-0035 705
Calibration Cup S3KCAL
XNX EC - The calibration cup is used to apply calibration test gas to the sensor.
It push ts onto the bottom of the sensor and can be tted without removing the
weatherproof cover.

Table of Contents

Other manuals for Honeywell XNX-UT Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Honeywell XNX-UT Series and is the answer not in the manual?

Honeywell XNX-UT Series Specifications

General IconGeneral
BrandHoneywell
ModelXNX-UT Series
CategoryTransmitter
LanguageEnglish

Related product manuals