Cut Charts and Marking Charts
128 809240 Operator Manual Powermax45 XP
Stainless Steel – FineCut – Air – Shielded and Unshielded
Metric
Material Thickness Current
Torch-to-Work
Distance
Initial Pierce Height Pierce Delay Time
Recommended
Kerf Width
Cut Speed Voltage
mm A mm mm % seconds mm/min volts mm
0.5
40
0.5 2.0 400
0.0
8250 68 0.6
0.6 8250 68
0.5
0.8 0.1 8250 68
1
45
0.2 8250 68 0.6
1.5
0.4
6150 70
1.0
2 4800 71
3 0.5 2550 81 1.4
40.61050841.5
English
Material Thickness Current
Torch-to-Work
Distance
Initial Pierce Height Pierce Delay Time
Best Quality Settings
Kerf Width
Cut Speed Voltage
inches A inches inches % seconds in/min volts inches
26 GA
40
0.02 0.08 400
0.0
325 68 0.024
24 GA 325 68 0.021
22 GA
0.1
325 68 0.018
20 GA 325 68 0.017
18 GA
45
0.2 325 68 0.036
16 GA
0.4
240 70 0.039
14 GA 200 70 0.040
12 GA 0.5 120 80 0.049
10 GA 0.6 75 83 0.055
Gas flow rate – slpm / scfh
155 / 330 Hot (cutflow)
215 / 460 Cold (postflow)
220955 (deflector)
220948 (shield)
220854
220953 (ohmic)
220930 220857220842
ARC WELDING SUPPLIES - 07 847 7870