Routine Maintenance
11
152 809240 Operator Manual Powermax45 XP
Every use
Every consumable change or weekly (whichever is more frequent)
System Torch
Check the indicator LED lights and correct
any fault conditions. See page 143.
Inspect the consumables for proper
installation and wear. See page 154.
Torch
Test the torch-disable switch to make sure it
properly disables and activates the torch:
1. With the plasma power supply turned
ON, set the torch-disable switch to the
yellow lock (X) position.
2. Point the torch away from yourself and
others. Pull the trigger to make sure that
the torch does not fire an arc. For the
machine torch, run a START/STOP
command from the CNC.
3. Set the torch-disable switch to the
green “ready to fire” ( ) position.
4. Point the torch away from yourself and
others. Pull the trigger 1 time. For the
machine torch, run a START/STOP
command from the CNC. Make sure
that the torch does not fire an arc. Make
sure that instead the torch emits
multiple puffs of air in quick succession.
Seepage45.
Replace the torch-disable switch if it is not
working properly. See page 159.
ARC WELDING SUPPLIES - 07 847 7870

Table of Contents

Other manuals for Hypertherm Powermax45 XP

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Hypertherm Powermax45 XP and is the answer not in the manual?

Hypertherm Powermax45 XP Specifications

General IconGeneral
BrandHypertherm
ModelPowermax45 XP
CategoryWelding System
LanguageEnglish

Related product manuals