EasyManuals Logo
Home>Hypertherm>Welding System>Powermax45 XP

Hypertherm Powermax45 XP User Manual

Hypertherm Powermax45 XP
174 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #157 background imageLoading...
Page #157 background image
Routine Maintenance
11
Powermax45 XP Operator Manual 809240 157
13. Put the air filter bowl back into place by screwing the
metal guard into the air filter assembly that is inside the
power supply.
Make sure the air filter bowl remains straight as
you install it. Otherwise, you may damage the
threads on the bowl.
14. Reconnect the gas supply to the back of the power
supply.
15. Reconnect the power cord, and set the power switch to
ON (I).
ARC WELDING SUPPLIES - 07 847 7870

Table of Contents

Other manuals for Hypertherm Powermax45 XP

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Hypertherm Powermax45 XP and is the answer not in the manual?

Hypertherm Powermax45 XP Specifications

General IconGeneral
BrandHypertherm
ModelPowermax45 XP
CategoryWelding System
LanguageEnglish

Related product manuals