36
7
CALL PROCEDURE
2001 NEW
Test call
Testing on the exclusive DSC distress and safety call-
ing frequencies (such as 2187.5 kHz) should be
avoided as much as possible by using other methods.
When testing on the distress/safety frequency is un-
avoidable, it should be indicated that these are test
transmissions.
Normally the test call would require no further commu-
nications between the two stations involved.
q Push [MODE
SET
] to select the DSC menu.
w Rotate [CH] to select Test call, then push
[ENT].
e Select the desired coast station code, then push
[ENT].
Use [CH] to select the coast station code when pre-pro-
grammed.
When Manual set is selected, enter the desired
code (last 7 digits only) via keypad.
-The first 2 digits 00 (double zero) are fixed for the
coast station code.
r Select the desired call frequency, then push [ENT].
Use [CH] to select one of the desired distress/safety
frequencies.
When Manual set is selected, enter the desired
transmit and receive frequencies via the keypad.
t The calling stand-by screen is displayed as fol-
lows, verify the calling condition then push and
hold [CANCEL/CALL] for 1 sec. to transmit the test
call.
y After sending a call, the transceiver waits for an ac-
knowledgement.
u When receiving an acknowledgement, the display
shows the received ID code, or ID name, if pro-
grammed.
************************
*
Test
ACK
*
*
ABC Port
*
************************
Exit
RX
J2B
GPS
<
Wait
for
ACK
>
Test
Lat
34
34'N
Lon135
34'E
12:34
SP
Exit
*********
Test
*********
---------
Call
---------
To:007654321
Call
Freq:TX
2187.5kHz
RX
2187.5kHz
Call
*********
Test
*********
----
Call
frequency
----
TX:_2187.5kHz
RX:_2187.5kHz
OKSEL
*********
Test
*********
----
Call
frequency
----
Manual
set
2187.5kHz
4207.5kHz
6312.0kHz
8414.5kHz
12577.0kHz
16804.5kHz
Ç
OKSEL
*********
Test
*********
------
Address
ID
------
007654321
OK
*********
Test
*********
------
Address
ID
------
Manual
set
Port
ICOM
001234567
Port
ABC
001234566
Port
M802
001234565
Ç
OKSEL
IC-M802_USA.qxd 02.5.30 11:40 Page 36

Table of Contents

Other manuals for Icom IC-M802

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Icom IC-M802 and is the answer not in the manual?

Icom IC-M802 Specifications

General IconGeneral
BrandIcom
ModelIC-M802
CategoryTransceiver
LanguageEnglish

Related product manuals