APPENDIX B
AX411 Access Point Power Guidelines,
Requirements, and Specifications
This section includes the following topics:
AX411 Access Point Site Electrical Wiring Guidelines on page 81
AX411 Access Point Power Supply Specifications and Requirements on page 82
AX411 Access Point Site Electrical Wiring Guidelines
Table 18 on page 81 describes the factors you must consider while planning the electrical
wiring for the AX411 Access Point at your site.
CAUTION: It is particularly important to provide a properly grounded and
shielded environment and to use electrical surge-suppression devices.
Table 18: Site Electrical Wiring Guidelines for the AX411 Access Point
GuidelineSite Wiring Factor
To ensure that signaling functions optimally:
Install wires correctly.
Improperly installed wires can emit radio interference.
Do not exceed the recommended distances or pass wires
between buildings.
The potential for damage from lightning strikes increases if wires
exceed recommended distances or if wires pass between
buildings.
Shield all conductors.
The electromagnetic pulse (EMP) caused by lightning can
damage unshielded conductors and destroy electronic devices.
Signaling limitations
81Copyright © 2012, Juniper Networks, Inc.