Page #436 background image
SCPI Command Subsystems
D-14
[:SENSe[1]]
:FREQuency
:THReshold
:CURRent
:RANGe <n>
:RANGe?
:LEVel <n>
:LEVel?
:VOLTage
:RANGe <n>
:RANGe?
:LEVel <n>
:LEVel?
:TTL
Path to configure threshold:
Path to set current threshold:
Specify range (0 to 1).
Query range.
Specify threshold level.
Query threshold level.
Path to set voltage threshold:
Specify range (0 to 1000).
Query range.
Specify threshold level.
Query threshold level.
Set threshold to TTL level.
:TEMPerature
:APERture <n>
:AUTO <b>
:AUTO ONCE
:AUTO?
:APERture?
:NPLCycles <n>
:AUTO <b>
:AUTO ONCE
:AUTO?
:NPLCycles?
:REFerence <n>
:STATe <b>
:STATe?
:ACQuire
:REFerence?
:DIGits <n>
:AUTO <b>
:AUTO ONCE
:AUTO?
:DIGits?
:AVERage
:TCONtrol <name>
:TCONtrol?
:COUNt <n>
:COUNt?
[:STATe] <b>
[:STATe]?
:AUTO <b>
:AUTO ONCE
:AUTO?
:TRANsducer <name>
:TRANsducer?
Path to configure four-wire resistance:
Specify integration rate in seconds (166.67e-6 to 200e-3).
Enable (1 or ON) or disable (0 or OFF) auto aperture.
Enable and then disable auto aperture.
Query auto aperture (0 or 1).
Query aperture (integration rate).
Specify integration rate in number of line cycles (0.01 to 10).
Enable (1 or ON) or disable (0 or OFF) auto NPLC.
Enable and then disable auto NPLC.
Query auto line cycle integration (0 or 1).
Query line cycle integration rate.
Specify reference (REL) value.
Enable (1 or ON) or disable (0 or OFF) REL.
Query state of REL (0 or 1).
Use input signal as reference.
Query reference (REL) value.
Specify measurement resolution (4 to 9).
Enable (1 or ON) or disable (0 or OFF) auto resolution.
Enable and then disable auto resolution.
Query auto resolution (0 or 1).
Query resolution.
Path to configure and control the filter.
Select filter type: MOVing, REPeat.
Query filter type.
Specify filter count (1 to 100).
Query filter count.
Enable (1 or ON) or disable (0 or OFF) filter.
Query state of digital filter.
Enable (1 or ON) or disable (0 or OFF) auto filter.
Enable and then disable auto filter.
Query auto filter.
Select transducer: RTD, FRTD, TCouple.
Query transducer.
Table D-7 (cont.)
SENSe command summary
Command Description

Table of Contents

Other manuals for Keithley 2001

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Keithley 2001 and is the answer not in the manual?

Keithley 2001 Specifications

General IconGeneral
BrandKeithley
Model2001
CategoryMultimeter
LanguageEnglish

Related product manuals