3-24
PC210/240-ENG
23. MAINTENANCE SCHEDULE CHART
SERVICE ITEM PAGE
(EVERY 500 HOURS SERVICE)
Replace hydraulic tank breather element 3-60
EVERY 1000 HOURS SERVICE
Change oil in swing machinery case 3-61
Check oil level in damper case, add oil 3-62
Check all tightening parts of turbocharger 3-62
Check play of turbocharger rotor 3-62
Replace hydraulic filter element 3-63
Check and adjust valve clearance (1
st
1000 hour only) 3-63
Check fan belt tensioner bearing, belt and fan hub 3-64
Check fan belt tension 3-64
EVERY 2000 HOURS SERVICE
Change oil in final drive case 3-65
Clean hydraulic tank strainer 3-66
Clean, check turbocharger 3-67
Check alternator, starting motor 3-67
Check vibration damper 3-67
Change antifreeze 3-67
Check and adjust valve clearance 3-67
EVERY 4000 HOURS SERVICE
Check water pump 3-68
EVERY 5000 HOURS SERVICE
Change oil in hydraulic tank 3-69
23.2 MAINTENANCE WHEN USING
HYDRAULIC BREAKER
For machines equipped with a hydraulic breaker, the hydraulic oil
deteriorates faster than for normal bucket digging operations, so set the
maintenance intervals as follows.
Replacing hydraulic filter element
On new machines, replace the element after the first 100 to 150 hours,
then carry out further replacement of the element according to the ta-
ble on the right.
Changing oil in hydraulic tank
Change the oil according to the table on the right.