bizhub PRO C5501 3-11
Adjustment
3
3.1.5 02 Scanner Adjustment \ 01 Restart Timing Adjustment
Perform this adjustment to control the restart timing in scanning the original with the original glass.
To specify Restart Timing Adjustment
1 Touch [Adjustment] on the Machine Status Screen.
The Adjustment Menu Screen will be displayed.
2 Touch [01 Machine Adjustment], [02 Scanner Adjustment], and then [01 Restart Timing Adjustment].
The Scanner Restart Timing Adjustment Screen will be displayed.
3 Touch [COPY] tab.
The Copy Screen will be displayed.
4 Select A3 w/11" e 17" w paper, place the original of which a misalignment can be easily monitored on
the original glass, then press [START].
5 Check the misalignment by comparing the original and the output.
6 If the desired result cannot be obtained, touch the [ADJUSTMENT] tab.
The Scanner Restart Timing Adjustment Screen will be restored.