119PERIODIC SERVICE
BChecking Water Separator
1. When the water has collected upper limit in the water
separator, the water separator indicator on the
instrument panel lights up and warning buzzer
sounding.
2. In such case, loosen the drain plug by several turns.
3. Allow water to drain. When no more water comes out
and fuel starts to flow out, retighten the drain plug.
4. Bleed the fuel system.
(See "SERVICE AS REQUIRED" in "PERIODIC
SERVICE" section.)
A [M6-101, M6-111]
When the red float reaches near the upper limit level,
start from step 2 in the above procedure to drain water
in the water separator.
A If water is drawn through to the fuel pump, extensive
damage will occur.
(1) Water separator indicator
(1) Red float
(2) Cup
(3) Drain plug
(A) "FUEL"
(B) "UPPER LIMIT"
(C) "WATER"